infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Housing Assembly HVAC > < High-Pressure Flexible Hose|Page 5237
Page 2
background image

13. Remove mounting bolt, and then remove low-pressure pipe 1 and high-pressure pipe 2.

CAUTION:  Cap or wrap the joint of expansion valve with suitable material such as vinyl tape to avoid the entry of air.

INSTALLATION

Installation is basically the reverse order of removal.

CAUTION:

-

Replace O-rings of low-pressure flexible hose, low-pressure pipe 1 and high-pressure pipe 1, 2 with new ones, and then apply compressor
oil to it when installing it.

-

Female-side piping connection is thin and easy to deform. Slowly insert the male-side piping straight in axial direction.

-

Insert piping securely until a click is heard.

-

After piping connection is completed, pull male-side piping by hand to make sure that connection does not come loose.

-

When recharging refrigerant, check for leaks.

Low-pressure flexible hose bracket mounting bolt torque : 4.2 N.m (0.43 kg-m, 37 in-lb)

Housing Assembly HVAC > < High-Pressure Flexible Hose|Page 5237