NOTE: Turning the screw (A) clockwise directs the laser beam downward (B). The laser beam directs upward (C) when turning screw
counterclockwise.
5. When "U/D CORRECT" value indicates ±4, confirm that the margin of value remains within ±4 at least for 2 seconds with no equipment or hand
touching the ICC sensor integrated unit.
When "COMPLETED THE VERTICAL AIMING OF LASER BEAM" appears on screen, touch "END".
CAUTION: Be sure that the margin of "U/D CORRECT" is within ±4 after leaving with ICC sensor integrated unit for 2 seconds or
more.
6. Confirm that "ADJUSTING AUTOMATIC HORIZONTAL LASER BEAM AIMING" is on screen and wait for a while (maximum: 10 seconds)
.
7. Confirm that "Normally Completed" is displayed on CONSULT-III and close the aiming adjustment procedure by touching "End".
CAUTION: Perform all the procedures once "LASER BEAM ADJUST" mode is entered in CONSULT-III. When the procedure is
discontinued, the ICC system is inoperable.
CHECK AFTER THE ADJUSTMENT
Test the ICC system operation by ICC system running test. Refer to ACS-14, "ICC System Running Test". See: Cruise Control/Testing and
Inspection/Initial Inspection and Diagnostic Overview/Action Test