EXHAUST MANIFOLD & THREE WAY CATALYST

Install exhaust manifold gasket with its directional protrusion set upward.
Refer to illustration of components.

EXHAUST MANIFOLD - TORQUE SEQUENCE

Tightening Exhaust Manifold Nuts 
Install exhaust manifold and three way catalyst in the numerical order shown in the figure.

Tighten nuts No. 1 to No. 4 in two steps. Order No. 9 to 12 shows second step.

Installation of Heated Oxygen Sensor 

CAUTION: When using heated oxygen sensor wrench (KV10114400), tighten to the middle of specified torque because length of tool may induce sight

indication increase. (Do not tighten to the maximum specified torque)
Before installing a new heated oxygen sensor, clean exhaust system threads using oxygen sensor thread cleaner tool, J-43897-18 or
J-43897-12, and apply anti-seize lubricant.
Do not over torque the heated oxygen sensor. Doing so may cause damage to the heated oxygen sensor, resulting in the MIL coming on.