infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Relays and Modules - Exhaust System > < Exhaust System|Specifications|Page 4354
Page 2
background image

Install mounting rubbers on rear main muffler as shown.

CAUTION: Always replace exhaust gaskets with new ones when reassembling.

Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 mm (19.7 inch) onto a hard surface such as a
concrete floor; use a new one.

Before installing a new oxygen sensor, clean exhaust system threads using oxygen sensor thread cleaner tool, J-43897-18 or J-43897-12,
and apply anti-seize lubricant.

Do not over torque the oxygen sensor. Doing so may cause damage to the oxygen sensor, resulting in the MIL coming on.

If the insulator is badly deformed, repair or replace it. If deposits such as mud pile up on the insulator, remove them.

When installing the insulator avoid large gaps or interference between the insulator and each exhaust pipe.

Remove deposits and left over gasket material from the sealing surface of each connection. Connect them securely to avoid gas leakage.

Temporarily tighten mounting nuts on the exhaust manifold side and mounting bolts on the vehicle side. Check each part for abnormal
interference, and then tighten them to the specified torque.

When installing each clamp, align the protrusion on the insulator with the clamp hole.

When installing each mounting rubber, avoid twisting or abnormal extension in up/down and right/left directions.

INSPECTION AFTER INSTALLATION 
With the engine running, check exhaust tube joints for gas leakage and unusual noises.

Check to ensure that mounting brackets and mounting insulators are installed properly and free from undue stress. Improper installation could result in
excessive noise and vibration.

Relays and Modules - Exhaust System > < Exhaust System|Specifications|Page 4354