Canister Vent Valve: Testing and Inspection

Component Inspection

EVAP CANISTER VENT CONTROL VALVE

With CONSULT-II

1. Remove EVAP canister vent control valve from EVAP canister.

2. Check portion B of EVAP canister vent control valve for being rusted.
3. Reconnect harness connectors disconnected.
4. Turn ignition switch "ON".
5. Perform "VENT CONTROL/V" in "ACTIVE TEST" mode.

6. Check air passage continuity and operation delay time.
7. Clean the air passage (Portion A to B ) of EVAP canister vent control valve using an air blower.
8. Perform Test No. 9 again.

Without CONSULT-II

1. Remove EVAP canister vent control valve from EVAP canister.

2. Check portion B of EVAP canister vent control valve for being rusted.