26.

After about one minute has passed, check the CONSULT-II's battery voltage reading on the CONSULT-II screen (see Figure 4).

NOTE: 

CONSULT-II's battery voltage is called "BATTERY VOLTAGE".

A.

If CONSULT-II's battery voltage ("Battery Voltage") is less than 8 volts:

^

Turn OFF CONSULT-II

^

Charge the CONSULT-II battery before proceeding with TCM Reprogramming

OR

^

Connect the AC/DC power supply cord to CONSULT-II during the reprogramming procedure

B.

If CONSULT-II's battery voltage ("Battery Voltage") is more than 8 volts, proceed with the following step.

CAUTION: 

Do not attempt TCM Reprogramming if the CONSULT-II battery voltage is below the specified voltage. Permanent TCM damage can occur if the
battery does not maintain the minimum voltage during the TCM Reprogramming.

Step 2a: Confirm Vehicle Battery Voltage

27.

Connect CONSULT-II to the vehicle making sure the connector is fully plugged in.

28.

Turn the ignition switch ON (DO NOT start the vehicle).

29.

After about one minute has passed, check the vehicle's battery voltage reading on the CONSULT-II screen (see Figure 5).

NOTE:

The vehicle's battery voltage is called "Charger Input".