infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

A/T - Manual Mode Inoperative/DTC P1815 Set|Page 10898 > < A/T - Manual Mode Inoperative/DTC P1815 Set|Page 10896
Page 6
background image

24.

Disconnect CONSULT-II from the vehicle and the AC/DC power cord.

25.

Press "SUB MODE", then select "BATTERY CHARGE".

26.

After about one minute has passed, check the CONSULT-II's battery voltage reading on the CONSULT-II screen (see Figure 4).

NOTE:

CONSULT-II's battery voltage is called "BATTERY VOLTAGE".

A.

If CONSULT-II's battery voltage ("Battery Voltage") is less than 8 volts:

^

Turn OFF CONSULT-II

^

Charge the CONSULT-II battery before proceeding with TCM Reprogramming

OR

^

Connect the AC/DC power supply cord to CONSULT-II during the reprogramming procedure

B.

If CONSULT-II's battery voltage ("Battery Voltage") is more than 8 volts, proceed with the following step.

CAUTION:

Do not attempt TCM Reprogramming if the CONSULT-II battery voltage is below the specified voltage. Permanent TCM damage can occur if
the battery does not maintain the minimum voltage during the TCM Reprogramming.

Step 2a: Confirm Vehicle Battery Voltage

27.

Connect CONSULT-II to the vehicle making sure the connector is fully plugged in.

28.

Turn the ignition switch ON (DO NOT start the vehicle).

A/T - Manual Mode Inoperative/DTC P1815 Set|Page 10898 > < A/T - Manual Mode Inoperative/DTC P1815 Set|Page 10896