infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Solar Sensor, HVAC > < Diagram Information and Instructions|Page 1135
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

Removal and Installation for Refrigerant Pressure Sensor

1. Remove condenser.
2. Remove refrigerant pressure sensor from condenser.

INSTALLATION

Installation is the reverse order of removal. Note the following.

CAUTION: When working, be careful not to damage the compressor fan.

Apply compressor oil to refrigerant pressure sensor O-ring prior to installation.

Tightening torque :  ..............................................................................................................................................................  9.8 - 11.7 N-m (1.0 - 1.2 kg.m)

Removal and Installation for Refrigerant Pressure Sensor (To be applied after the middle of June 2001.)

1. Use refrigerant collecting equipment (for HFC134a) to discharge refrigerant.
2. Remove front grille.

3. Disconnect connector and remove refrigerant pressure sensor.

INSTALLATION

Installation is the reverse order of removal. Note the following.

CAUTION: Be careful not to deform pipe during the operation.

Be careful not to damage the core surface of the condenser during the operation.
Replace refrigerant pressure sensor O-ring with a new one. Apply compressor oil prior to installation.

Refrigerant pressure sensor
Tightening torque :  ..............................................................................................................................................................  9.8 - 11.7 N-m (1.0 - 1.2 kg.m)

Solar Sensor, HVAC > < Diagram Information and Instructions|Page 1135