infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Campaign - Acceleration Hesitation/Delay|Page 11131 > < Campaign - Acceleration Hesitation/Delay|Page 11129
Page 20
background image

1.

Remove the Diagnostics Card (blue) and install the ECM Reprogramming Software Card (orange) into slot A of CONSULT-II (see Figure 1).

2a.

Connect the AC power supply to CONSULT-II.

2b.

Connect CONSULT-II to the ASIST PC with the special Ethernet cable (P/N 02002554, printed on the cable) contained in the CONSULT-II kit.

NOTE:

Connect the special Ethernet cable to the ASIST PC by connecting it to the Ethernet card connection port located on the back of the computer.
Connect the special Ethernet cable to CONSULT-II at the PC port located at the bottom end of the CONSULT-II unit.

3.

Confirm the CONSULT-II date and time is correctly set as follows:

A.

With the ECM Reprogramming Software card in slot A, turn on CONSULT-II.

B.

Touch "Sub Mode".

C.

Touch "Set Date".

^

If date is not correct, touch the month, day or year as needed. Then adjust it by using arrow keys. Once done, press "Save", press "Back"
and go to step D.

^

If date is OK, press "Back" and go to step D.

D.

Touch "Set Time".

^

If time is not correct, touch the hour, minute or AM/PM as needed. Then adjust it by using arrow keys. Once done, press "Save", press
"Back" and go to step 4.

^

If time is OK, press "Back" and go to step 4.

Campaign - Acceleration Hesitation/Delay|Page 11131 > < Campaign - Acceleration Hesitation/Delay|Page 11129