infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

All Technical Service Bulletins for Refrigerant:|96-041 > < Special Tool - A/C Leak Detector
Page 2
background image

5.

To calibrate the D-TEK, slowly pass the probe tip about ... of an inch over the leak reference bottle, moving the probe about 1 - 2 inches per
second to detect a leak rate of 0.5 ounces per year (see Figure 2). The alarm will sound and several yellow lamps will illuminate. Once the yellow
lamps go out, the unit will have an audible click (about 2 clicks per second) which indicates the D-TEK is ready to use.

6.

Visually inspect the entire A/C system for any signs of leakage or damage. If any are found, clean those areas thoroughly with a clean shop rag to
prevent contamination to the D-TEK's probe.

7.

Start the leak inspection at the compressor and move the probe (1 to 2 inches per second and no further than ... inch from the components) in a
continuous path along the high side line though the condenser core, receiver drier, evaporator, and back to the compressor on the low side line.

8.

To inspect the evaporator core, first place the blower fan on high with the AC compressor off for 15 seconds. Then turn the fan off and allow the
system to set for 13 minutes. Inspect the evaporator drain hose and passenger side foot duct.

CAUTION: Do not allow the probe tip to contact water.

NOTE: When a leak is detected, the D-TEK will emit a different audible tone, and the yellow lamps will illuminate. It is important to move the
probe past the suspected leak to get a proper reading as the D-TEK responds to changes in the concentration of refrigerant.

9.

When the D-TEK signals a leak, pull the probe away for a moment, blow area with shop air, and then return it to the same location to isolate the
leak. If the leak is large, move the sensitivity switch to LOW.

10.

Return the sensitivity setting to HI and continue looking for other possible leaks until the entire A/C system is inspected.

NOTE: When you reset the instrument to the HI sensitivity setting, as when you turned the unit ON initially, the yellow lights will illuminate and
the tone will sound again momentarily.

All Technical Service Bulletins for Refrigerant:|96-041 > < Special Tool - A/C Leak Detector