infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Solar Sensor, HVAC|Testing and Inspection|Page 9507 > < Solar Sensor, HVAC|Testing and Inspection|Page 9503
Page 1
background image

Solar Sensor: Testing and Inspection

COMPONENT DESCRIPTION

The sunload sensor is located on the right defroster grille. It detects sunload entering through windshield by means of a photo diode. The sensor converts
the sunload into a current value which is then input to the auto amplifier.
Measure voltage between auto amp. terminal (10) and body ground.

SUNLOAD INPUT PROCESS

The auto amp. also includes a processing circuit which "average" the variations in detected sunload over a period of time. This prevents drastic swings in
the ATC system operation due to small or quick variations in detected sun load.
For example, consider driving along a road bordered by an occasional group of large trees. The sunload detected by the sun load sensor will vary
whenever the trees obstruct the sunlight. The processing circuit averages the detected sunload over a period of time, so that the (insignificant) effect of
the trees momentarily obstructing the sunlight does not cause any change in the ATC system operation. On the other hand, shortly after entering a long
tunnel, the system will recognize the change in sunload, and the system will react accordingly.

Solar Sensor, HVAC|Testing and Inspection|Page 9507 > < Solar Sensor, HVAC|Testing and Inspection|Page 9503