infiniti Workshop Repair Guides

Infiniti Workshop Service and Repair Manuals

Environmental Impact Information|Page 9233 > < Environmental Impact Information|Page 9231
Page 2
background image

The A/C system contains a fluorescent leak detection dye used for locating refrigerant leaks. An ultraviolet (UV) lamp is required to illuminate the dye
when inspecting for leaks.

Vehicles With Factory Installed Fluorescent Identification Label

IDENTIFICATION LABEL

Location:  ..........................................................................................................................................................................................  Underside of Hood.
Color:

With Factory Installed Flourenscent Dye:  ........................................................................................................................................................  Green.
Without Factory Installed Flourenscent Dye:  .....................................................................................................................................................  Blue.

Always wear fluorescence enhancing UV safety glasses to protect your eyes and enhance the visibility of the fluorescent dye.

The fluorescent dye leak detector is not a replacement for an electronic refrigerant leak detector. The fluorescent dye leak detector should be used in
conjunction with an electronic refrigerant leak detector to (J-41995) pin-point refrigerant leaks.

For your safety and your Customer's satisfaction, read and follow all manufacture's operating instructions and precautions prior to performing the work.

A compressor shaft seal should not be repaired because of dye seepage. The compressor shaft seal should only be repaired after confirming the leak with
an electronic refrigerant leak detector (J-41995).

Always remove and dye from the leak area after repairs are complete to avoid a misdiagnosis during a future service.

Do not allow dye to come into contact with painted body panels or interior components. If dye is spilled, clean immediately with the approved dye
cleaner. Fluorescent dye left on a surface for an extended period of time cannot be removed.

Do not spray the fluorescent dye cleaning agent on hot surfaces (engine exhaust manifold, etc.).

Do not use more than one refrigerant dye bottle (1/4 ounce /7.4 cc) per A/C system.

Leak detection dyes for R-134a and R12 A/C systems are different. Do not use R-134a leak detection dye in R-12 A/C system or R-12 leak detector dye
in R-134a A/C systems or A/C system damage may result.

The fluorescent properties of the dye will remain for over three (3) years unless a compressor failure occurs.

Service Equipment

Precautions For Service Equipment

RECOVERY/RECYCLING EQUIPMENT

Be certain to follow the manufacturers instructions for machine operation and machine maintenance. Never introduce any refrigerant other than that
specified into the machine.

ELECTRONIC LEAK DETECTOR

Be certain to follow the manufacturer's instructions for tester operation and tester maintenance.