QX56 V8-5.6L (VK56DE) (2004)
Management/Computers and Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Reading Diagnostic
Trouble Codes/With Manufacturer's Scan Tool (CONSULT II)
4. Touch "BUZZER" or "BCM".
5. Select "DATA MONITOR" or "SELF-DIAG RESULTS".
DATA MONITOR
Operation Procedure
1. Touch "BUZZER" on "SELECT TEST ITEM" screen.
2. Touch "DATA MONITOR" on "SELECT DIAG MODE" screen.
3. Touch "ALL SIGNALS" or "SELECTION FROM MENU" on "DATA MONITOR" screen.
4. If "SELECTION FROM MENU" is selected, touch the item you desire to monitor. If "ALL SIGNALS" is selected, all control items are
monitored.
5. Touch "START".
6. During monitoring, touching "RECORD" can start recording the monitored item status.
Display Item List
Display Item List
ACTIVE TEST
Operation Procedure
1. Touch "BUZZER" on "SELECT TEST ITEM" screen.
2. Touch "ACTIVE TEST" on "SELECT DIAG MODE" screen.
3. Touch the item to be tested, and check the operation.
4. During the operation check, touching "OFF" deactivates the operation.