QX56 V8-5.6L (VK56DE) (2004)
3. Install A/T fluid temperature sensor 2 (with bracket) in control valve with TCM. Tighten A/T fluid temperature sensor 2 mounting bolt to the
specified torque.
CAUTION: Adjust bolt hole of bracket to bolt hole of control valve with TCM.
4. Install control valve with TCM in transmission case.
CAUTION: Make sure that turbine revolution sensor securely installs turbine revolution sensor hole.
^
Hang down revolution sensor harness toward outside so as not to disturb installation of control valve with TCM.
^
Adjust A/T assembly harness connector of control valve with TCM to terminal hole of transmission case.