8. Prepare the Fluke Meter and the Phototach Digital Tachometer for the next test as follows.

a. Switch the Fluke Meter to read DC Volts.

b. Remove the Phototach Digital Tachometer from its case and have it ready to check the fan RPM.

NOTE:  

It is important that readings from these two meters be read and recorded at the same time in the next test.

Figure B-5

Figure B-6

c. Practice using the Phototach Digital Tachometer as follows:

1. Do not turn the fan motor tester ON at this time.

2. Press and hold the TEST button on the Phototach Digital Tachometer.

WARNING: 

Do not shine or point the red light beam from the Phototach Digital Tachometer into anyone's eyes (including your own).

3. Hold the digital tachometer about 4 inches away from the condenser fan.

4. Aim the red beam at the painted area on the fan blade.

-

The beam should be aimed between / through the slots in the fan shroud.