isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

EVAP Canister Vacuum Switching Valve <--> [Canister Purge Solenoid]|Testing and Inspection > < EVAP Canister Vacuum Switching Valve <--> [Canister Purge Solenoid]|Specifications|Page 1416
Page 1
background image

EVAP Canister Vacuum Switching Valve: Description and Operation

Evaporative Emission Control System

PURPOSE

Controls canister purge operation.

Canister And Pressure Regulator Vacuum Switching Valve

LOCATION

On R.H. fender apron.

OPERATION

The ECM controlled canister purge vacuum switching valve (VSV) is in the vacuum line to the purge control valve.  Normally closed, the VSV
opens when energized by the ECM.  During idle or cold operation, the VSV is closed (de-energized), preventing canister purging.  The ECM
energizes the VSV to permit canister purge only under these conditions:

-

Engine at operating temperature.

-

Engine must run for a specified length of time.

-

Vehicle must be operating above a specified road speed.

-

Throttle must be open more than a specified angle.