isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Leak Check - Repair of Refrigerant Leaks|Page 3383 > < Leak Check - Repair of Refrigerant Leaks|Page 3381
Page 4
background image

refrigerant will leak out.

Leak at Refrigerant Line Connections

1. Check the torque on the refrigerant line fitting and, if too loose, tighten to the specified torque.

-

Use two wrenches to prevent twisting and damage to the line.

-

Do not over tighten.

2. Perform a leak test on the refrigerant line fitting.
3. If the leak is still present, discharge and recover the refrigerant from the system.
4. Replace the O-rings.

-

O-rings cannot be reused. Always replace with new ones.

-

Be sure to apply the specified compressor oil to the new O-rings.

5. Retighten the refrigerant line fitting to the specified torque.

-

Use two wrenches to prevent twisting and damage to the line.

6. Evacuate, charge and retest the system.

Leaks In The Hose

If the compressor inlet or outlet hose is leaking, the entire hose must be replaced. The refrigerant hose must not be cut or spliced for repair.

1. Locate the leak.
2. Discharge and recover the refrigerant.
3. Remove the hose assembly.

-

Cap the open connections at once.

4. Connect the new hose assembly.

-

Use two wrenches to prevent twisting or damage to the hose fitting.

-

Tighten the hose fitting to the specified torque.

5. Evacuate, charge and test the system.

Compressor Leaks

If leaks are located around the compressor shaft seal or shell, replace or repair the compressor.

Leak Check - Repair of Refrigerant Leaks|Page 3383 > < Leak Check - Repair of Refrigerant Leaks|Page 3381