isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Power Transistor HVAC > < Leak Check - Repair of Refrigerant Leaks|Page 3382
Page 1
background image

Hose/Line HVAC: Service and Repair
Removal and Installation

Removal

1. Disconnect the battery ground cable.

2. Discharge and recover refrigerant.

-

Refer to Refrigerant Recovery in this section.

3. Remove the front bumper assembly.

-

Refer to Front Bumper in Body Structure section.

4. Remove the condenser air guide.
5. Remove the front side turn signal light (LH).
6. Remove the head light (LH).
7. Remove clip and clamp.
8. Disconnect liquid line (High-pressure pipe).
9. Disconnect suction line (Low-pressure pipe) using a back-up wrench.

10. Disconnect suction line (Low-pressure hose) using a back-up wrench.

11. Disconnect discharge line (High-pressure hose) using a back-up wrench.

-

Use a backup wrench when disconnecting and reconnecting the refrigerant lines.

-

When removing the refrigerant line connecting part, the connecting part should immediately be plugged or capped to prevent foreign matter
from being mixed into the line.

Installation

To install, follow the removal steps in the reverse order, noting the following point:

1. O-rings cannot be reused. Always replace with new ones. 
2. Be sure to apply new compressor oil to the O-rings when connecting lines.
3. Tighten the refrigerant line to the specified torque.

Refer to Main Data and Specifications for Torque Specifications in this section.

Power Transistor HVAC > < Leak Check - Repair of Refrigerant Leaks|Page 3382