isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Leak Check - Repair of Refrigerant Leaks|Page 3416 > < Leak Check - Repair of Refrigerant Leaks|Page 3414
Page 3
background image

ACR(4)(or equivalent) Method

Refrigerant Recovery

For the charging of refrigerant recovered by ACR(4)(or equivalent), follow the manufacturer's instruction.

Direct charging with a weight scale charging station method

1. Make sure the evacuation process is correctly completed.
2. Connect the center hose of the manifold gauge to the weight scale.
3. Connect the low pressure charging hose of the manifold gauge to the low pressure side service valve of the vehicle.

Leak Check - Repair of Refrigerant Leaks|Page 3416 > < Leak Check - Repair of Refrigerant Leaks|Page 3414