Axiom 2WD V6-3.5L (2002)
ACR(4)(or equivalent) Method
Refrigerant Recovery
For the charging of refrigerant recovered by ACR(4)(or equivalent), follow the manufacturer's instruction.
Direct charging with a weight scale charging station method
1. Make sure the evacuation process is correctly completed.
2. Connect the center hose of the manifold gauge to the weight scale.
3. Connect the low pressure charging hose of the manifold gauge to the low pressure side service valve of the vehicle.