isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 4111 > < Diagram Information and Instructions|Page 4109
Page 7
background image

Frequently, a diagnostic chart leads to a step that reads: Check for poor connection. Mating terminals must be inspected to assure good terminal
contact. A poor connection between the male and female terminal at a connector may be the result of contamination or deformation.

Contamination is caused by the connector halves being improperly connected, a missing or damaged connector seal, or damage to the connector
itself, exposing the terminals to moisture and dirt. Contamination, usually in underhood or underbody connectors, leads to terminal corrosion,
causing an open circuit or intermittently open circuit.

Deformation Of A Typical Metric-Pack 150/280/480/630 Series Female Terminal

Deformation is caused by probing the mating side of a connector terminal without the proper adapter, improperly joining the connector halves or
repeatedly separating and joining the connector halves. Deformation, usually to the female terminal contact tang, can result in poor terminal
contact, causing an open or intermittently open circuit.

PROCEDURE

Follow the procedure below to check terminal contact.

Diagram Information and Instructions|Page 4111 > < Diagram Information and Instructions|Page 4109