Hombre L4-2.2L CPC (1996)
Proper Taping
Step 3: Prepare the Splice
Untwist the conductors. Then, prepare the splice by following the splicing instructions for copper wire presented earlier. Remember to stagger
splices to avoid shorts.
Step 4: Re-assemble the Cable
After you have spliced and taped each wire, rewrap the conductors with the mylar tape. Be careful to avoid wrapping the drain wire in the tape.
The Re-Assembled Cable
Next, splice the drain wire following the splicing instructions for copper wire. Then, wrap the drain wire around the conductors and mylar tape.
The Untwisted Conductors
Step 5: Tape the Cable
Tape over the entire cable using a winding motion. This tape will replace the section of the jacket you removed to make the repair.
General Information
^
The following general repair procedures can be used to repair most types of connectors. The repair procedures are divided into three general
groups: Push-to-Seat, Pull-to-Seat and Weather Pack(R).
^
Use the proper Pick(s) or Tool(s) that apply to the terminal.
^
The Terminal Repair Kit (J 38125-A) contains further information.
Push-to-Seat and Pull-to-Seat Connectors
Typical Push-to-Seat Connector And Terminal