isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Starting System > < Gauge - Voltmeter Displays High or Low|Page 3455
Page 2
background image

2. Install the generator attaching bolts. 

Tighten
2.1. Tighten the left generator bolt to 30 Nm (22 ft. lbs.).
2.2. Tighten the right generator bolt to 43 Nm (32 ft. lbs.)

NOTICE:  Refer to Fastener Notice in Service Precautions.

3. Connect the BAT feed wire to the generator.  

Tighten

Tighten the BAT feed terminal nut to 8 Nm (71 inch lbs.).

4. Connect the electrical connector to the generator.

5. Install the generator rear brace to the engine, working through the wheel well.

NOTICE:  Refer to Fastener Notice in Service Precautions.

6. Install the generator rear brace attaching bolt and nuts.

Tighten

Tighten the generator brace nuts and bolt to 30 Nm (22 ft. lbs.).

7. Install the accessory drive belt. Refer to Drive Belt Replacement.
8. Connect the negative battery cable.

Starting System > < Gauge - Voltmeter Displays High or Low|Page 3455