Auxiliary Power Outlet: Description and Operation
Retained Accessory Power

feature allows the Power Windows, Sunroof, Overhead Console and the Entertainment System to be operated after the ignition Switch is turned from the
RUN position to the LOCK position. The BCM monitors the ignition switch position, door jamb switches and the voltage on Circuit (755). The BCM
will command the RAP relay ON by grounding circuit 755 when all the doors are closed and the ignition switch is in the OFF position. Once the RAP
relay is energized, the accessories will remain operational until any one of the following conditions are met:

1. The 20 minute timer has elapsed.
2. Driver / Passenger door has been opened.
3. Door handle switch has been activated.
4. The ignition switch turned to the RUN position.