isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Fusible Links|Page 3532 > < Fusible Links|Page 3530
Page 1
background image

Fusible Link: Service and Repair

Fusible Links

Good And Damaged Fusible Links

In addition to circuit breakers and fuses, some circuits use fusible links to protect the wiring. Like fuses, fusible links are "one-time" protection devices
that will melt and create an open circuit.

Not all fusible link open circuits can be detected by observation. Always inspect that there is battery voltage past the fusible link to verify continuity.

Fusible links are used instead of a fuse in wiring circuits that are not normally fused, such as the ignition circuit. For AWG sizes, each fusible link is four
wire gauge sizes smaller than the wire it is designed to protect. For example: to protect a 10 gauge wire, use a 14 gauge link or for metric, to protect a 5
Sq.mm
 wire, use a 2 Sq.mm link. Links are marked on the insulation with wire-gauge size because the heavy insulation makes the link appear to be a
heavier gauge than it actually is. The same wire size fusible link must be used when replacing a blown fusible link.

Fusible links are available with three types of insulation: Hypalon, Silicone/ GXL (SIL/GXL) and Expanded Duty. All future vehicles that use fusible
links will utilize the Expanded Duty type of fusible link. When servicing fusible links, all fusible links can be replaced with the Expanded Duty type.
SIL/GXL fusible links can be used to replace either SIL/GXL or Hypalon fusible links. Hypalon fusible links can only be used to replace Hypalon
fusible links.

Determining characteristics of the types of fusible links are:

-

Hypalon (limited use): only available in 0.35 mm or smaller and its insulation is one color all the way through.

-

SIL/GXL (widely used): available in all sizes and has a white inner core under the outer color of insulation.

-

Expanded Duty: available in all sizes, has an insulation that is one color all the way through and has three dots following the writing on the
insulation.

Service fusible links are available in many lengths. Choose the shortest length that is suitable. If the fusible link is to be cut from a spool, it should be cut 
150-225 mm (approx. 6-9 inches.) long. NEVER make a fusible link longer than 225 mm (approx. 9 inches.).

Fusible Links|Page 3532 > < Fusible Links|Page 3530