9. Remove the manual detent spring bolt.
10. Remove the manual detent spring.
11. Remove the remaining control valve body bolts.
12. Disconnect the manual valve link and remove the control valve body from the transmission case.
13. Inspect the control valve body. Refer to the Transmission/Transaxle/Transfer Case Unit Repair Manual for cleaning, inspection, and repair
procedures of the control valve body.
Installation Procedure
1. Install the control valve body and connect the manual valve link to the transmission case.
2. Check that the manual valve link (3) is installed properly to the inside detent lever (1) and the manual valve (2).
Important: When installing bolts throughout this procedure, be sure to use the correct bolt in the correct location as specified.
3. Install the control valve body bolts.