isuzu Workshop Repair Guides

Isuzu Hombre S Space Cab 2WD V6-43L Workshop Service and Repair Manuals

Accessory Delay Module|Testing and Inspection > < Diagram Information and Instructions|Page 4912
Page 1
background image

Accessory Delay Module: Description and Operation

The retained accessory power (RAP) feature allows you to operate the following components after the ignition switch is turned from the RUN position to
the LOCK position:

-

The power windows

-

The radio

The BCM monitors the following components:

-

The ignition switch position

-

The doorjamb switches

-

The voltage on CKT 755

The BCM commands the RAP relay to turn ON by grounding CKT 755.This action is completed when all of the doors are closed and the ignition switch
is turned to the OFF position. Once the RAP relay is energized, the accessories remain operational until any one of the following conditions exists:

-

The 20 minute timer elapses.

-

The driver/passenger door is opened. 

-

The ignition switch is activated.

Accessory Delay Module|Testing and Inspection > < Diagram Information and Instructions|Page 4912