Blower Motor Resistor: Service and Repair

NOTE:  Do not allow the metal coils of the blower resistor to become grounded to any metal surface. This may result in internal circuitry damage.

CAUTION:  Refer to Battery Disconnect Caution in Cautions and notes.

1. Disconnect the battery negative cable.
2. Remove the blower resistor harness.

3. Remove the stud from the dash panel.
4. Remove the blower motor resistor (1).

Installation Procedure

1. Install the blower motor resistor (1).
2. Install the stud to the dash panel.
3. Install the resistor harness.
4. Connect the battery negative cable.