Refrigerant Pressure Sensor / Switch: Service and Repair
Pressure Sensor

Removal Procedure

1. Disconnect the refrigerant pressure sensor electrical connector.

2. Remove the refrigerant pressure sensor from the evaporator tube.
3. Remove and discard the O-ring seal from the refrigerant sensor port on the evaporator tube.

Installation Procedure