isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Vehicle Speed Sensor > < Throttle Position Sensor|Locations|Page 1725
Page 5
background image

5. Install the air cleaner outlet duct
6. Tighten the air cleaner outlet duct wing nut.

7. Secure the air cleaner outlet duct to the MAF sensor.

Tighten: Tighten the air cleaner outlet duct clamp to 4 N.m (35 lb in).

8. Connect the breather tube to the air cleaner outlet duct.
9. Connect the IAT sensor harness connector.

10. Connect the negative battery cable.

Vehicle Speed Sensor > < Throttle Position Sensor|Locations|Page 1725