Hombre XS Space Cab 2WD L4-2.2L CPC (1999)
1. Coat the threads of the heated oxygen sensor with anti-seize compound if necessary.
2. Install the sensor using J 39194 HO2S Removal tool.
Tighten
Tighten the sensor to 41 N.m (30 lb ft).
NOTE: Refer to Fastener Note in Service Precautions.
3. Install the HO2S 2 electrical connector.
4. Lower the vehicle.