isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Hydraulic Control Assembly - Antilock Brakes|Removal and Installation|Page 3234 > < Hydraulic Control Assembly - Antilock Brakes|Removal and Installation
Page 2
background image

Tighten
Tighten the three alien bolts to 8 Nm (6 ft. lbs.), then to 16 Nm (12 ft. lbs.)
.

NOTICE:  Refer to Fastener Notice in Cautions and Notices.

IMPORTANT: 
-

Do not reuse the old EBCM mounting bolts. Always install new mounting bolts with the new EBCM.

-

Do not use RTV or any other type of sealant on the EBCM gasket or mating surfaces.

4. Install the EBCM gasket (3) onto the BPMV (4). Inspect Insure gasket alignment is correct.
5. Install EBCM(2)onto BPMV(4).
6. Install the four new EBCM bolts (1).

Tighten
Tighten the four bolts to 5 Nm (39 inch lbs.) in an X-pattern
.

7. Install BPMV(4) to bracket.
8. Install the three BPMV (4) to bracket retaining bolts.

Tighten
Tighten the three bolts to 9 Nm (7 ft. lbs.)
.

9. Connect the four electrical connectors to the EBCM.

10. Install the EHCU to the vehicle frame.

Tighten
Tighten the three bolts to 12 Nm (9 ft. lbs.)
.

11. Install the right front, left front and rear brake pipes to the tube adapters.

Tighten
Tighten the three brake pipe fittings to 30 Nm (22 ft. lbs.)
.

12. Install the front and rear brake pipes (from master cylinder) to the combination valve.

Tighten
Tighten the three brake pipe fittings to 30 Nm (22 ft. lbs.)
.

13. Connect the electrical connector to the combination valve.
14. Install the two fuse block mounting bolts from the EBCM bracket.
15. Connect the negative battery cable. Important: Verify that the combination valve metering rod is depressed during bleeding.
16. Bleed the brake system. Refer to ABS Bleed Procedure.
17. Return to Diagnostic System Check.

Hydraulic Control Assembly - Antilock Brakes|Removal and Installation|Page 3234 > < Hydraulic Control Assembly - Antilock Brakes|Removal and Installation