i-290 2WD L4-2.9L (2008)
Variable Valve Timing Solenoid: Service and Repair
Camshaft Position Actuator Solenoid Valve Replacement
Removal Procedure
1. Disconnect the engine wiring harness electrical connector (1) from the camshaft position (CMP) actuator solenoid valve (6).
2. Remove the CMP actuator solenoid valve bolt (3).
3. Remove the CMP actuator solenoid valve (2) from the cylinder head.
Discard the O-ring seal.
4. Clean debris from the hole (1).
Installation Procedure
1. Install a new O-ring seal to the actuator solenoid valve (2).
2. Lightly lubricate the O-ring seal with clean engine oil.
3. Install the CMP actuator solenoid valve (2) into the cylinder head.
Notice: Refer to Fastener Notice (See: Service Precautions/Vehicle Damage Warnings/Fastener Notice) .
4. Install the camshaft position actuator solenoid valve bolt (3).
Tighten the CMP actuator solenoid valve bolt to 10 N.m (89 lb in).