Valve Cover: Service and Repair

Camshaft Cover Replacement 
Removal Procedure 

1. Remove the intake manifold.
2. Remove the ignition coils.

3. Disconnect the following electrical connectors from the camshaft cover.

^

The engine coolant temperature (ECT) sensor (1)

^

The fuel injector (2)

^

The heated oxygen sensor (HO2S) (5)

4. Remove the fuel pressure regulator screw, in order to gain clearance to remove the camshaft cover.

5. Remove the camshaft cover bolts.
6. Remove the camshaft cover from the cylinder head.
7. Remove the seals from the camshaft cover.Do not reuse the seals.
8. Clean and inspect the cylinder head sealing surface.
9. Clean and inspect the camshaft cover. Refer to Camshaft Cover Cleaning and Inspection.

Installation Procedure 

1. Install a NEW camshaft cover seal into the camshaft cover groove.
2. Install NEW ignition control module seals into the camshaft cover grooves.