isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Air Door Cable, HVAC > < Air Door Actuator / Motor, HVAC|Locations|Page 6447
Page 1
background image

Air Door Actuator / Motor: Service and Repair

RECIRCULATION ACTUATOR REPLACEMENT

REMOVAL PROCEDURE

1. Remove the HVAC module assembly.

2. Remove the recirculation actuator screws.
3. Remove the electrical connector (3) from the recirculation actuator (2).
4. Remove the recirculation actuator.

INSTALLATION PROCEDURE

1. Install the recirculation actuator (2).
2. Install the screws to the recirculation actuator.

Tighten the screws to 1.9 N.m (17 lb ft).

NOTE:  Refer to Fastener Notice in Service Precautions.

3. Connect the electrical connector (3) to the recirculation actuator (2).
4. Install the HVAC module assembly.

Air Door Cable, HVAC > < Air Door Actuator / Motor, HVAC|Locations|Page 6447