1. Install the HVAC control assembly.
2. Connect the HVAC control assembly electrical connectors.
3. Connect the mode cable to the HVAC control assembly.

IMPORTANT:  Do not bend the mode and temperature cables.

4. Connect the temperature cable to the HVAC control assembly.

5. Install the HVAC control assembly to the instrument panel.
6. Install the HVAC control assembly screws.

Tighten the screws to 1.9 N.m (18 lb in).

NOTE:  Refer to Fastener Notice in Service Precautions.

7. Install the accessory trim plate.