9. Using the heat torch, apply heat to the crimped area of the barrel.

10. Gradually move the heat barrel to the open end of the tubing:

-

The tubing will shrink completely as the heat is moved along the insulation.

-

A small amount of sealant will come out of the end of the tubing when sufficient shrinkage is achieved.

SIR/SRS SYSTEM WIRE SPLICE REPAIR

Apply a new splice (not sealed) from the J 38125 if damage occurs to any of the original equipment splices (3 wires or more) in the SIR/SRS wiring
harness. Carefully follow the instructions included in the kit for proper splice clip application.

CONNECTOR POSITION ASSURANCE (CPA)

The connector position assurance (CPA) is a small plastic insert that fits through the locking tabs of all the SIR/SRS system electrical connectors. The
CPA ensures that the connector halves cannot vibrate apart. You must have the CPA in place in order to ensure good contact between the SIR/SRS
mating terminals.

TERMINAL POSITION ASSURANCE (TPA)

The terminal position assurance (TPA) insert resembles the plastic combs used in the control module connectors. The TPA keeps the terminal securely
seated in the connector body. Do not remove the TPA from the connector body unless you remove a terminal for replacement.

Connector Position Assurance Locks

CONNECTOR POSITION ASSURANCE LOCKS

The connector position assurance (CPA) is a small plastic insert that fits through the locking tabs of the connector. CPAs are used in various connectors
throughout the vehicle. CPAs are also used in all SIR system electrical connectors. The CPA ensures that the connector halves cannot vibrate apart. You
must have the CPA in place in order to ensure good contact between the mating terminals, of the connector.

Terminal Position Assurance Locks

TERMINAL POSITION ASSURANCE LOCKS

The terminal position assurance (TPA) insert resembles the plastic combs used in the control module connectors. The TPA keeps the terminal securely
seated in the connector body. Do not remove the TPA from the connector body unless you remove a terminal for replacement.

Bosch Connectors (BSK)

BOSCH CONNECTORS (BSK)

TOOLS REQUIRED

J 38125 Terminal Repair Kit

TERMINAL REMOVAL PROCEDURE

1. Disconnect the connector from the component.
2. Remove the wire dress cover if necessary.
3. Push the wire side of the terminal that is being removed toward the connector and hold it in position.