i-350 L5-3.5L (2006)
Input Shaft: Service and Repair
Transmission Input Shaft Bearing Retainer Replacement
Transmission Input Shaft Bearing Retainer Replacement
Removal Procedure
1. Drain the transmission fluid.
2. Remove the clutch actuator cylinder.
3. Remove the input shaft bearing retainer bolts. Discard the bolts
4. Remove the input shaft bearing retainer.
5. Clean and inspect the input shaft bearing retainer. Refer to Transmission Case Cleaning and Inspection (Colorado) Transmission Case Cleaning
and Inspection (Solstice) in Manual Transmission-Aisin AR5 Unit Repair.
Installation Procedure
1. Apply a 3 mm (1/8 inch) bead of sealant GM P/N 89020326 (Canadian P/N 89021188) to the input shaft bearing retainer.