i-350 L5-3.5L (2006)
1. Lightly lubricate the NEW O-ring seal (2) with clean transfer case fluid.
2. Insert the O-ring seal (2) into the transfer case.
3. Important: Ensure the encoder motor is seated flat against the transfer case.
Position the encoder motor (3) to the transfer case, aligning the actuator shaft.
4. Notice: Refer to Fastener Notice in Service Precautions.
Install the encoder motor mounting bolts, with the heated oxygen sensor bracket (1).
^
Tighten the encoder motor mounting bolts to 22 Nm (16 ft. lbs.).
5. Connect the following to the encoder motor (7):
^
The electrical connector (8)
^
The vent hose
6. Lower the vehicle.