I-Mark L4-1471cc 1.5L (1987)
Ignition Coil: Testing and Inspection
Ignition Coil Resistance Measurements
Primary Coil Resistance Measurement
1.
Place ignition switch in the ``Off'' position.
2.
Disconnect ignition coil terminals, then measure resistance between ignition coil positive terminal and ignition coil negative terminal.
3.
If resistance is not 1.2-1.5 ohms, replace coil.
Secondary Coil Resistance Measurement
1.
Place ignition switch in the ``Off'' position.
2.
Disconnect ignition coil terminals, then measure resistance between ignition coil positive terminal and high voltage terminal.
3.
If resistance is not 10,200-13,800 ohms, replace coil.
Insulation Resistance Measurement
1.
Place ignition switch in the ``Off'' position.
2.
Disconnect ignition coil terminals, then measure resistance between ignition coil positive terminal and body.
3.
If resistance is not 10m ohms or more, replace coil.