isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

1. Recovery|Page 314 > < 1. Recovery
Page 2
background image

1.

Use only DOT approved containers and evacuate to at least 27 in Hg (75 mm Hg absolute pressure) before transferring refrigerant.

2.

To prevent overfilling during transfer, never fill container more than 60% of its gross weight rating (18 lb. in a 30 lb. container and 30 lb. in a 50 lb.
container).

EVACUATING DISPOSABLE CONTAINERS

1.

"Empty" disposable containers still contain traces of refrigerant.  Evacuate before disposing of container.

2.

Connect recovery/recycling unit to container and evacuate remaining refrigerant.  Once container shows a vacuum, close valve.  Mark container
"EMPTY" and properly dispose of.

Discharge System

Refrigerant recovery and recycling stations facilitate recovery and reuse of refrigerant after contaminants and moisture have been removed.

When using a recovery or recycling station, follow manufacturer's operating instructions and note the following:

1.

Use extreme caution and observe all safety and service precautions related to refrigerant use.

2.

Connect refrigerant recycling station hose(s) to vehicle A/C service port(s) and recovery station inlet fitting. Hoses used should have shutoff
devices or check valve within 12 inches of hose ends to minimize introduction of air into recycling station and to minimize amount of refrigerant
release when hose(s) is disconnected.

3.

Turn on recycling station to start recovery process. Allow recycling station to pump refrigerant from A/C system until station pressure gauge
indicates vacuum.

4.

After vehicle A/C system has been evacuated, close station inlet valve, if equipped.

5.

Turn station Off. On some stations the pump will automatically be turned off by a low pressure switch.

6.

Allow vehicle A/C system to remain closed for approximately two minutes. Observe vacuum level indicated on gauge. If pressure does not rise,
disconnect recycling station hose(s).

7.

If system pressure rises, repeat steps 3 through 6 until vacuum level remains stable for two minutes.

8.

Service A/C system as necessary.

9.

Evacuate and recharge A/C system.

1. Recovery|Page 314 > < 1. Recovery