isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Testing Using A Digital VOM|Page 623 > < Oxygen Sensor|Locations|Page 620
Page 1
background image

Oxygen Sensor: Testing and Inspection
Testing Using A Digital VOM

Fig. 210 Disconnecting Oxygen Sensor Harness

Fig. 211 Inserting Tester Jumper and Lead to Oxygen Sensor Harness

1.

The output of the oxygen sensor can be checked with a voltmeter having a minimum input resistance (impedance) of 1 megohm (1 million ohms).

2.

Proceed as follows:

a. Disconnect the oxygen sensor from the vehicle harness, Fig. 210.
b. Insert a jumper with exposed wire between the sensor and the harness to ease probing, Fig. 211.
c. Set the voltmeter to the 2 volt scale.
d. Connect the positive lead of the voltmeter to the jumper and the negative lead to vehicle ground.
e. Start the engine and run at 2500 rpm for 2 minutes or until the engine has gone into "closed loop" operation.
f.

The meter should move between approx. 0.50 and 0.80 volts.

Testing Using A Digital VOM|Page 623 > < Oxygen Sensor|Locations|Page 620