isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Rear A/C Unit|Page 5346 > < Rear A/C Unit|Page 5344
Page 1
background image

Evaporator Case: Service and Repair
Front A/C Unit

EVAPORATOR / REPLACEMENT

1.  Recover the refrigerant with a Recovery/Recycling/Charging System.

Evaporator Replacement

2.  Disconnect the receiver line and the suction line from the evaporator.

NOTE: Plug or cap the lines immediately after disconnecting them to avoid moisture and dust contamination.

3.  Remove the dashboard lower cover, center console and the stops from the glove box.

Evaporator Replacement

4.  Remove the damper from the glove box and the connectors from the glove box frame. Remove the two bolts and the glove box frame together with

the glove box.

Rear A/C Unit|Page 5346 > < Rear A/C Unit|Page 5344