Oasis LS L4-2156cc 2.2L SOHC MFI F22B6 (1997)
Maintenance Bleeder
2. Connect the rubber tube to the bleeder on the modulator unit, and set the other end of the rubber tube in a container.
3. Loosen the bleeder, and start the engine to activate the pump motor.
NOTE: Take care not to spill the brake fluid from the container.
4. Tighten the bleeder when the fluid starts to flow out of the bleeder.
5. Stop the engine after the pump motor stops
NOTE: If the ABS indicator light comes on and the pump motor stops, restart the engine and repeat steps 3 through 5 above.