Radiator Cooling Fan Temperature Sensor / Switch: Pressure, Vacuum and Temperature
Specifications

Thermoswitch "ON" Temp. .............................................................................................................................................................  194 - 205°F (90 - 96°C)
Thermoswitch "OFF" Temp. [1] ................................................................................................................................................................  4 - 13°F (2 - 7°C)
Fan Timer "ON" Temp. ...............................................................................................................................................................  217 - 228°F (103 - 109°C)
Fan Timer "OFF" Temp. [1] ......................................................................................................................................................................  7 - 16°F (4 - 9°C)

[1] Subtract this value from the actual "ON" temp.