Harmonic Balancer - Crankshaft Pulley > < Crankshaft Inspection|Page 990
Page 7
background image

NOTE:  
^

Apply liquid gasket 4 mm wide.

^

Apply liquid gasket doubly to the jointing point of the liquid gasket.

27. Tighten the bolts/nuts in two or three steps. In the final step, tighten all bolts/nuts, in sequence to 12 Nm (1.2 kgs.m, 8.7 ft. lbs.).