Oasis S L4-2253cc 2.3L SOHC VTEC MFI (1998)
-
Inlet valve closed, outlet valve open
-
Caliper fluid flows through the outlet valve to the reservoir.
Motor Operation Mode:
-
When starting the pressure reduction mode, the pump motor is ON.
-
When stopping ABS operation, the pump motor is OFF.
-
The reservoir fluid is pumped out by the pump, through the damping chamber, to the master cylinder.