isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Distributor Replace|Page 516 > < Distributor Replace
Page 1
background image

Distributor: Service and Repair
Distributor Service

Disassembly

Fig. 4 Distributor exploded view.

Refer to Fig. 4 during disassembly procedure.

1.

Remove distributor cap, O-ring and rotor.

2.

Remove igniter/signal generator cover.

3.

Remove igniter/signal generator attaching screws, then the igniter/signal generator.

4.

Remove snap ring, then pull out vacuum advancer.

5.

Remove breaker plate attaching screws, then the breaker plate.

6.

Pre-drill collar retaining pin using a suitable drill press, then remove pin using suitable punch.

7.

Remove collar from governor shaft, then separate governor shaft from distributor housing.

8.

Remove two springs from signal rotor, then the signal rotor cap.

9.

Remove signal rotor attaching screw and signal rotor from governor shaft.

10.

Remove snap rings and two weights.

Inspection

1.

Check distributor cap and rotor for cracks and carbon tracks.

Distributor Replace|Page 516 > < Distributor Replace