Vacuum Switch: Description and Operation
Vacuum Switching Valve--Calif.

Fig. 22 Typical vacuum switching valve

The Vacuum Switching Valve, Fig. 22, has 3-way ports, two of which are operated by an electrically controlled solenoid plunger which is energized
when the coolant temperature is below 122 degrees F or for 10 seconds after the Wide Open Throttle (WOT) switch is energized with the coolant
temperature above 122 degrees F. 
The solenoid plunger is de-energized immediately after the WOT switch is turned off during this 10 second period.
When energized, the Vacuum Switching Valve connects diaphragm chamber ``B'' of the air switching valve to intake manifold, allowing application of
manifold vacuum. When the solenoid plunger is de-energized, the Vacuum Switching Valve ports are closed, thereby diaphragm chamber ``A'' is
connected to diaphragm chamber ``B''. 