2.

Determine fast charge amperage (Figure 1). Fast charge battery for 30 minutes at amperage rate no higher than specified in Figure 1. Take voltage
reading after charge.

a.

If voltage is above 16 V, replace battery.

b.

If voltage is between 12 V and 16 V, continue charging at the same rate for an additional 3-1/2 hours.

c.

Perform load test as described below.

3.

Load test battery as follows. This procedure is based on the Sun VAT 40 starting/charging system tester, check the manufacturer's operating
instructions if using a different machine.

a.

Set tester LOAD CONTROL and FUNCTION SELECTOR knobs to OFF.

b.

Connect red clamp of tester lead to POSITIVE battery terminal.

c.

Connect black clamp of tester lead to NEGATIVE battery terminal.

d.

Attach inductive amp probe around red test cable. Allow on probe must be facing the battery.

e.

Remove surface charge from battery.

f.

Set FUNCTION SELECTOR knob to BATTERY LOAD TEST.