testing electronic components. 

Proper Tools and Testing Procedures

DIGITAL VOLT/OHM METER

Use a digital volt/ohm meter (DVOM) with a minimum 10 mega-ohms internal impedance when testing an ECU or related components, unless use
of an analog meter is specified by a testing procedure.  Analog meters have low internal impedance and cause circuit "loading" in low voltage
circuits, resulting in inaccurate measurements and possible damage to components.  Use of a DVOM is necessary to obtain accurate measurements
and avoid damaging low voltage ECU circuits and components.

TESTING PROCEDURES

Always follow recommended testing procedures. Never ground or apply voltage to a circuit unless specified by a testing procedure. ECU's provide
a regulated constant low voltage source to some circuits, which may require a minimum resistance (impedance) to operate.  Directly grounding or
applying battery power to these circuits could damage the ECU and cause a system failure.

 

Finding Short Circuits

Meter Types

1.

Use a digital or analog multimeter with a minimum 10k ohm resistance.

2.

Remove the blown fuse and disconnect all loads for that circuit.